Patch cord 1 meter LC/UPC-SC/UPC True -Tech
Patch cord 1 meter LC/UPC-SC/UPC
The LC/UPC-SC/UPC Fiber Patch Cord Duplex SM G.657.A1 2.0mm 1m Yellow (Part number: 2LCU-SCU.S3-2DXJ1.1mY) from Mikrolink Fiber is a Duplex patch cord with LC/UPC connector at one side and a SC/UPC connector at the other one. Fiber patch cords are a type of cables that have two connectors on both ends. Optic patch cords can come in simplex (1 fiber), duplex (2 fibers) or in MPO (12 fibers). The connectors on both sides of the patch cord, allow it to be quickly connected to another device such as an optical switch or other telecommunications/computer device.
- Singlemode
- Polishing UPC
- Return loss ≥ 55 dB (unmated), >60 dB (mated)
- Insertion loss ≤ 0,25 dB (Grade B1)
- Ferrule material Ceramic (zirconia)
- Ferrule diameter 1.25 mm / 2.5 mm
- Insertion / extraction cycles Min. 1000
Cable Mechanical Properties
- Attenuation @ 1310 / 1383 / 1550 nm (dB/km) ≤ 0,4 / ≤ 0,4 / ≤0,4
Customers also search by: Fiber Patch Cord, Fiber Optic Patch Cord, Fiber Patch Lead
PRODUCT SPECIFICATIONS
Cabled optical fiber OS2
Nominal diameter core / sheath 9 / 125 μColor YeOuter diameter 1.6 mm to 3 mmSheath material LSZH, UL-94 V0Bending radius (static) 45 mm
Temperature range -20°C +70°C
Attenuation @ 850 / 1300 nm (dB/km) ≤ 3,2 / ≤ 0,8OS2 G.657.A1
Fiber Type (ITU) – OS2 G.657.A1
Each type of single-mode fiber has its own area of application, and the evolution of these optical fiber specifications reflects the evolution of transmission system technology from the earliest installation of single-mode optical fiber to the present day. Choose the right fiber is very important for each project/installation. The OS2 G.657 standard single-mode fibers were developed to allow a better bending radius regarding the G.652 standard. For the OS2 G.657 fiber there are 4 subcategories: G.657.A1, G.657.A2, G.657.B2, G.657.B3. The G.657.A1 fiber type is characterized by 10 mm minimum bending radius. These specifications of the G.657 fibers allow to have a better cost-efficiency due to compact cable designs and reduced space requirements.
Configuration – Duplex
A Duplex configuration is a type of cabling arrangement commonly used in data centers and telecommunication networks. It consists of a two fibers cable , terminated with two connector at each end. It is normaly used in Simplex data transmition.
FO Connector Type 1 – LC
LC FO Connector is a small form factor fiber optic connector that uses a 1,25mm ceramic ferrule to align and connect optical fibers. Used in high-speed communication networks.Provides low insertion loss and high return loss. The connector is easy to install and provides a secure and reliable connection for both single-mode and multimode fiber optic cables. Its compact size makes it ideal for applications where space is limited, such as data centers, telecommunication rooms, and fiber-to-the-home installations.
FO Polish Connector 1 – UPCUPC (Ultra Phisical Contact), is a type of polishing procedure that makes a connical end face ferrule minimizing the interference of dust particules in the connectors mate. It as a Return loss >-50dB. UPC connectors may only be mated with other UPC or PC connectors. It can be identified by the blue boot and is used in single-mode and multi-mode fibers.